Phase Meter - Model 6000A
0.020º Accuracy |
0.001º Resolution |
5Hz to 1MHz Frequency |
| Response |
Hi Resolution Color Display |
Isolated Inputs |
IEEE-488, USB |
|
 |
HIGHEST PERFORMANCE
The Model 6000A Phase Meter replaces the very popular Model 6000. Using the latest
digital techniques and optimally designed analog front end, the Model 6000A out-performs
any other phase meter on the market today. It also does this at a remarkably low cost. The
unit automatically selects the proper range for both amplitude and phase and is waveshape
independent. The user only needs to connect the two input cables to the phase meter to
obtain a phase reading. Voltage Overrange or Underrange is indicated whenever either of
the two input signals is too large or too small. An OFFSET toggle on the front panel
allows the user to make differential phase measurements without the need of subtracting
large numbers. The Model 6000A is galvanically isolated from ground and from channel to
channel.
IEEE-488 AND USB INTERFACE STANDARD
The Model 6000A Phase Meter has an IEEE-488.2 interface and USB as standard features.
Via these interfaces, the user can read the display, change the phase range, and check for
input signal overrange or underrange, front panel selected offset and phase range.
TWO PHASE RANGES
The Model 6000A Phase Meter has two user selectable phase ranges: The 0 º to 360º range and the ±180º range.
NOISE AND HARMONIC IMMUNITY
The Model 6000A, unlike previous generation phase meters, does not use
"zero-cross-over" techniques to measure phase. The instrument uses a
sophisticated Fourier Transform approach to derive the fundamental component of each of
the two the input signals and then computes the phase difference between the two
components. Harmonics and noise are effectively "filtered out". This technique
reduces errors significantly.
WAVESHAPE INDEPENDENT
The high accuracy of the Model 6000A Phase Meter is maintained not only for sinewaves
but also for distorted and noisy waves. Unique DFT circuitry produces waveform independent
phase readings; hence, the user does not have to activate any front panel waveform
selection switches. Two different waveforms of the same frequency may be applied to the
Phase Meter simultaneously.
HIGH VOLTAGE INPUT RATIOS
Specified accuracies are maintained not only with equal amplitude signals in both
channels but also with amplitude ratios over the entire dynamic voltage input range.
ROBUST INPUT PROTECTION
Unique input protection circuitry allows for the sudden application of high input
voltages without fear of damage to the Model 6000A Phase Meter. There is no need to slowly
increase the levels of input voltages.
FLOATING INPUTS
Neither input of the Model 6000A Phase Meter is connected to chassis ground nor is
connected to the other input; hence, measurements may be made on networks with "earth
ground" connections without creating ground loops with their resultant phase errors.
Very high common mode rejection is also achieved via fully galvanically isolated front
ends.
OPTIONAL DC OUTPUT
This option provides a ±DC output which is directly proportional to
phase. The sensitivity is -1 volt /degree.
Specifications
| Resolution |
0.001º |
| Accuracy |
5Hz to 2 KHz |
0.02º |
| |
>2KHz to 5KHz |
0.03º |
| |
>5KHz to 10KHz |
0.04º |
| |
>10KHz to 50KHz |
0.05º |
| |
>50KHz to 1MHz |
f (in kHz) X 0.001º |
| Frequency Response |
5Hz to 1MHz |
| Phase Ranges |
0º to 360º
or ±180º user selectable |
| Amplitude Range |
10mV to 630
Vrms |
| Input Impedance |
1Mohm in
parallel with 100pF |
| Response Time |
Less than 6
sec. to specified accuracy |
| Optional DC output |
+1.80V to
-3.60V DC |
| Optional DC Outputc Accuracy |
±10mVDC |
| Display |
High
Resolution TFT Color |
| Front Panel Controls |
Phase
OFFSET, LOCAL, Phase RANGE |
| Digital Interface |
IEEE-488.2
and USB |
| Temperature Range |
0º TO 40ºC
Operating
23ºC±5ºC within specification |
| Input Power |
90 to 264
VAC, 47 to 63Hz, 20VA |
| Dimensions |
17.3" W
X 3.5" H X 13" D |
| Weight |
9.7 Pounds |
Options:
01: DC output (order as Model 6000A-01)
02: Front and rear inputs (order as Model 6000A-02)
(For both options order as Model 6000A-01-02) |