DESCRIPTION
The Model 610 and 650 Current Shunts are specifically
designed to operate with the Model 6000A Precision Phase Meter. These shunts are frequency tuned to have
negligible phase shift (less than ± 5mº) at 50/60Hz making them ideal for line frequency
applications. They can also be idealized for
other frequencies as specified by the user. Consult
factory for details.
SPECIFICATIONS
| Model |
Current Range |
Frequency |
Phase
Shift |
| 610 |
1A to 10A |
5Hz to 1kHz
1kHz to 100kHz |
Less than 5mº
5mº+50mº(fkHz -1) |
| 650 |
10A to 50A |
5Hz to 100Hz
100Hz to 500Hz
500Hz to 1kHz |
Less than 5mº
Less than 10mº
50mº |
| The Model 610 and 650 are designed to drive the high input
impedance of the Model 6000A phase meter. Any other meter used with these
shunts must have an input resistance greater than 1Mohm in parallel with not more
than 100pF to avoid additional phase error. |
|